Genesys reverse osmosis chemicals
Genefloc GPF flocculant
Application: Improved performance of RO pre-filtration equipment
A general -purpose flocculant for use in surface, well and process waters with medium to high SDI values. Genefloc GPF should be dosed continuously to feed water allowing at least 5 minutes contact time before filtration. Typical dose rate of Genefloc GPF is 1-4mg/l.
Genesol 37
Application: Reverse Osmosis Low pH Membrane Cleaning
An inorganic strongly acidic cleaner effective for removal of inorganic scale and iron deposits in Reverse Osmosis and Nano-filtration membrane systems. Genesol 37 is highly effective when used as a 1-2% solution and alternately soaked and recycled through the membrane system for 1-2hours. At this concentration, its self-adjusting pH ensures highest solubility of iron deposits, inorganic scales and proteinous deposits.
Genesol 38
Application: Reverse Osmosis Low pH Membrane Cleaning
An inorganic scale cleaner and iron deposit remover for use in Reverse Osmosis and Nano-filtration membrane systems. Used at the right concentration, its self-adjusting pH ensures highest solubility of iron salts is achieved. Genesol 38 is highly effective when used as a 3-4% solution and alternately soaked and recycled through the membrane system for 4-6hours.
Genesol 701
Application: Reverse Osmosis Low pH Membrane Cleaning
An inorganic scale cleaner and iron deposit remover for use in Reverse Osmosis and Nano-filtration membrane systems. Used at the right concentration, its self-adjusting pH ensures highest solubility of iron salts is achieved. Genesol 38 is highly effective when used as a 3-4% solution and alternately soaked and recycled through the membrane system for 4-6hours.
Genesol 701
Application: Reverse Osmosis Low pH Membrane Cleaning
An inorganic scale cleaner and iron deposit remover for use in Reverse Osmosis and Nano-filtration membrane systems. Used at the right concentration, its self-adjusting pH ensures highest solubility of iron salts is achieved. Genesol 38 is highly effective when used as a 3-4% solution and alternately soaked and recycled through the membrane system for 4-6hours.
Genesol 703
Application: Reverse Osmosis High pH Membrane Cleaning
A general-purpose cleaner for organic based foulants found in Reverse Osmosis and Nano-filtration membrane systems with particular application in removal of aluminium silicate. It is highly effective at a solution of 1-2% at the maximum allowable pH recommended by the membrane manufacturer and should be alternately soaked and recycled through the membrane system for 4-6 hours. Cleaning with warm solutions is advised for improved efficiency. After cleaning, the membrane system should be thoroughly flushed out until the pH values of the feed and discharge are the same.
Genesol 704
Application: Reverse Osmosis High pH Membrane Cleaning
A general-purpose cleaner for a wide range of organic based foulants found in Reverse Osmosis and Nano-filtration membrane systems. Genesol 704 is particularly effective against aluminium silicate, which can be difficult to remove with conventional cleaners. It is also effective against most micro-organisms such as bacteria, fungi and algae. Genesol 704 should be used as a 1-2% solution at the maximum allowable pH recommended by the membrane manufacturer. It should be alternately soaked and recycled through the membrane system for 2-4 hours.
Genesol 32
Application: Reverse Osmosis membrane Biocidal Cleaning & preservative
A broad spectrum biocide used on and offline to eliminate microbiological fouling as well as a preservative. When used off-line, genesol 32 should be dosed at 1000- 1500mg/l for 6-8hours and if online, it should be dosed at 700-1000mg/l for 8-12 hours once every 5-21 days depending on severity. It can be used in pre-treatment system, i.e. pumps, tanks and pipework. After use, the membranes should be flushed and cleaned using an alkaline detergent. It is deactivated to harmless by-products by using Sodium Bisulphite.
Genesol LF
Application: Reverse Osmosis Antiscalant Pre-Treatment
A broad spectrum liquid antiscalant for use in Reverse Osmosis and Nano-filtration systems. It is effective at preventing inorganic scale, particularly calcium carbonate, iron and silica thus reducing the frequency of membrane replacement and cleaning. Genensys LF should be dosed continuously to the feed water upstream of the cartridge filters. Typical dosage rates are 2-5 mg/l.
Genesol SI
Application: Reverse Osmosis Antiscalant Pre-Treatment
An antifoulant for use in Reverse Osmosis and Nano-filtration systems operation on high silica feed-waters. Genesys SI is also effective against all common scale forming salts such as calcium carbonate, calcium, barium and strontium sulphate. Genesys SI should be dosed continuously to the feed water upstream of the cartridge filters. Typical dosage rates are 2-5mg/l.
Genesol RC
Application: Reverse Osmosis Antiscalant Pre-Treatment
A broad spectrum antiscalant and antifoulant for use in small and recycling Reverse 3 Osmosis and Nano-filtration systems with less than 100m /day of feed water flow. Genesys RC is effective at preventing all inorganic scale formation thus reducing the frequency of membrane cleaning and replacement. Genesys RC allows systems to be designed and operated at higher recovery rates. Genesys RC should be dosed continuously to the feed water upstream of the cartridge filter. Typical dosage rates are 7-15mg/l.